JetVent Car Park Ventilation
JetVent Car Park Ventilation


The Digital EC series of JetVent fans represents the next step in fully integrated car park ventilation systems. These energy efficient fans generate constant air movement ensuring pollutants do not gather in dead areas.
Energy Efficient
The JetVent Car Park fans feature advanced digital EC motor technology with integrated speed control. This enables them to clear harmful pollutants from enclosed or semi-enclosed car parks while minimising running costs.
Ultra Series
The newest addition to the Digital EC range. The JetVent Ultra Series feature an innovative and high performance mixed flow impeller with highly efficient blade geometry.
Smart Engineering
JetVent fans are positioned within the space to mix the air and direct it towards the main extraction fan intake points.
Compact Design
The JetVent Car Park is fully optimised and has a compact design which produces powerful thrust without increasing noise levels
Aviator MAX Controller
The Aviator MAX Control System is a tailored solution designed to efficiently manage the car park ventilation equipment. Aviator MAX has been developed to increase the energy efficiency of a car park, while ensuring the ventilation output is optimised.
Fans
JetVent Product Code | Description |
JIU-CPCEC-HP | High Performance |
JIU-CPCEC-SD | Standard |
JIU-CPCEC-LH | Low Height |
JIU-CPCEC-USD | Ultra Standard |
JIU-CPCEC-ULH | Ultra Low Height |
Controllers
Controller Product Code | Description |
DCV-CU-MAX1 | Aviator MAX car park controller |
DCV-CU-EXPANSION1 | Expansion module |
Dimensions

Product Code | A | Vertical Height B |
C | D | E | F | G | H | I | Approx. Weight Kg |
JIU-CPCEC-HP | 1,833 | 492 | 1,151 | 110 | 30 | 16 | 1,240 | 450 | 600 | 160 |
JIU-CPCEC-SD | 1,745 | 370 | 906 | 68 | 25 | 13 | 973 | 605 | 675 | 89 |
JIU-CPCEC-LH | 1,745 | 322 | 906 | 68 | 25 | 13 | 973 | 605 | 675 | 89 |
JIU-CPCEC-USD | 1,745 | 370 | 906 | 68 | 25 | 13 | 973 | 605 | 675 | 89 |
JIU-CPCEC-ULH | 1,040 | 262 | 488 | 55 | 20 | 12 | 537 | 350 | 410 | 26 |
All dimensions in mm
Technical Data
Product Code | Fan Speed | Thrust Rating |
Car Park Installed Noise Levels |
Free-Field Noise Rating |
Power Consumption |
Current | Input Power | ||||||
RPM | N | dB(A) @ 8m# | dB(A) @ 3m** | kW | A | ||||||||
High Speed | Pre-Set Speed* |
High Speed |
Pre-Set Speed* |
High Speed | Pre-Set Speed* |
High Speed |
Pre-Set Speed* |
High Speed | Pre-Set Speed* | High Speed | Pre-Set Speed* |
||
JIU-CPCEC-HP | 1,230 | 858 | 91.8 | 48.2 | 75.2 | 65 | 65.8 | 56.5 | 2.9 | 1.0~ | 4.8 | 1.6 | 415V |
JIU-CPCEC-SD | 1,770 | 1,296 | 52.2 | 28.4 | 72.4 | 65 | 64.4 | 56.7 | 1.7 | 0.7~ | 2.9 | 1.1 | 415V |
JIU-CPCEC-LH | 1,770 | 1,120 | 46.8 | 18.9 | 76.4 | 65 | 68.7 | 56.7 | 1.7 | 0.4~ | 2.9 | 0.8 | 415V |
JIU-CPCEC-USD | 1,450 | 1,400 | 38.9 | 36.5 | 66.5 | 65 | 58.3 | 56.7 | 1.1 | 1.1 | 1.8 | 1.8 | 415V |
JIU-CPCEC-ULH | 2,100 | 2,100 | 23 | 23 | 64.8 | 64.8 | 56.8 | 56.8 | 0.56 | 0.56 | 2.8 | 2.8 | 240V |
# Car park installed noise levels apply 8m away from the fan with multiple fans operating.
**Free-field noise rating applies 3m away from the fan with multiple fans operating.
Contact your nearest Elta Fans Applied Technology office to confirm if this is applicable to your installation.
~ Estimated power consumption.
* Pre-set speed so fan does not operate above the AS2107:2000 recommended noise level of 65dB(A) @ 8m.